Mohammad AskarPublic working copy · medical review pending

Eyelid malpositions · 057

Lid malpositions: identify the mechanism before surgery

Assess lid position, levator function, laxity and corneal protection together.

Public working copy · medical review pending. Source, translation and medical checks remain open. Read the limitations in the text and references. These educational materials do not replace individual medical assessment. Published: 2026-11-18T19:45:52+01:00. Internal project references lead to this notice. They are not publicly accessible primary sources; the source limitations remain stated in the text.

Match correction to cause and protect the ocular surface.

Terminology and draft status

Terminology review is not complete. Selected actual WHO UMD queries and their limits are recorded in terminology.md; they do not approve the whole translation.

01Ptosis: anatomy and cause

The levator palpebrae superioris, supplied by cranial nerve III, raises the upper lid through its aponeurosis at the tarsus and skin crease. Sympathetic Müller muscle adds approximately 2 mm of lift. Ptosis can arise from muscle, aponeurosis, innervation or mechanical load; levator function alone does not identify its cause. 1 2

Ask about congenital versus acquired onset, sudden change, daily variability or fatigue, family history, trauma and operations. Fluctuating ptosis suggests myasthenia but is not diagnostic. Myasthenia is a neuromuscular-junction disorder, not a primary muscle dystrophy; preserve its original table topic while correcting that mechanism. 1 2

Ptosis: anatomy and cause
TypeCause and clinical feature
CongenitalOften levator dystrophy, weak function and weak/absent crease
AponeuroticCommon acquired form, aponeurotic dehiscence, often good function and high crease
Myogenic/neuromuscularCPEO, myotonic dystrophy; myasthenia affects the junction
NeurogenicThird-nerve palsy or Horner syndrome with miosis and possible anhidrosis
MechanicalTumour, chalazion or scar weight
TraumaticInjury to levator or aponeurosis

02Measure position and protective function

Measure MRD1 from corneal reflex to upper margin in primary gaze, lid aperture, crease and levator excursion with brow immobilised. The original MRD1 4–5 mm and LF >8 mm good, 5–7 mm moderate and ≤4 mm poor are teaching categories, not universal population norms; the omitted boundary at 8 mm needs an explicit local convention. A high crease often supports aponeurotic ptosis, whereas an absent crease often supports congenital disease rather than both findings proving aponeurotic disease. 1

Check Bell phenomenon, closure and ocular surface before raising the lid: the usually upward and outward protective rotation varies. Raising a ptotic lid may reduce equal levator drive and allow the other lid to fall under Hering’s law; it does not automatically cause opposite-lid retraction. Cogan lid twitch is a myasthenia clue, not proof. Assess pupils, motility and jaw-linked movement as part of the same examination. 1 2

Measure position and protective function
MeasureHow to assessMeaning and limit
MRD1Corneal reflex to upper margin; approximately 4–5 mmNorm varies; quantify position
Lid apertureVertical opening at pupilCompare both eyes
LFBrow fixed, downgaze to upgaze>8 mm good, 5–7 mm moderate, ≤4 mm poor; boundary convention needed
CreaseHeight and strengthHigh often aponeurotic; absent often congenital
Bell phenomenonProtective globe rotation on attempted closureVariable; assess exposure risk
HeringLift ptotic lid and observe fellow lidFellow lid may fall; not automatic retraction
Specific testsCogan twitch and jaw-winkingClues interpreted with full examination

03Choose ptosis surgery in context

Good levator function often permits aponeurotic repair; mild selected phenylephrine-responsive ptosis may suit Müller muscle–conjunctival resection (MCR/MMCR). Levator resection with moderate function and frontalis suspension with poor function are options, not an automatic algorithm. The original 18–20 mm resection is an example, not a fixed dose. Consider severity, cause, Bell response, closure, dryness and the child’s visual-development risk together. 1 2

A fascia lata or silicone frontalis sling links lid elevation to brow action but requires counselling about closure and surface risk. Marcus–Gunn jaw-winking links trigeminal jaw activity with oculomotor levator activation: chewing, sucking or jaw movement lifts the lid. Selected severe cases may require levator disabling followed by a sling; this is not mandatory for every synkinesis. 1

Choose ptosis surgery in context
Original LF categoryOptionSelection limit
Good >8 mmAponeurotic repairAppropriate aponeurotic cause
Good >8 mmMCR/MMCRSelected mild phenylephrine-responsive ptosis
Moderate 5–7 mmLevator resection18–20 mm is an example, not a universal amount
Poor ≤4 mmFrontalis slingFascia lata or silicone; assess closure and surface

04Ectropion: laxity, scar or weakness

An everted margin can produce epiphora, conjunctivitis and corneal exposure. Distinguish involutional horizontal/canthal laxity from cicatricial anterior-lamellar vertical shortage, facial-nerve palsy and mechanical tumour or swelling. Delayed snap-back and the original distraction >8 mm suggest laxity but are not independent universal surgical thresholds. 1

Lateral tarsal strip (LTS) corrects selected horizontal laxity: lateral canthotomy and inferior cantholysis release the attachment; a de-epithelialised tarsal strip is shortened and fixed to lateral orbital periosteum with an appropriate vector. Scar shortage, medial malposition or paralysis may need additional or different repair. This outline is anatomical teaching, not a standalone operating protocol. 1

05Entropion: address the actual factors

An inverted lid causes lash contact, pain and foreign-body sensation with risk to the cornea; distinguish entropion from isolated trichiasis. Involutional mechanisms combine horizontal laxity, lower-lid retractor weakness/disinsertion and preseptal orbicularis overriding the pretarsal portion, reversing the original anatomical wording. Cicatricial causes include trachoma, chemical injury and ocular pemphigoid; spastic cases may occur after surgery. 1 3 4

Everting sutures, including Quickert techniques, can provide temporary or longer benefit in selected cases. LTS is useful when horizontal laxity contributes but is not almost always required; retractor repair such as Jones-type procedures addresses vertical instability. Randomised trials compared particular operations in primary involutional lower-lid disease, not all entropion causes. Discuss recurrence and surface care; no procedure guarantees prevention of inward rotation. 1 3 4

06Retraction and asymmetry

Upper-lid retraction may expose sclera above the limbus. Thyroid eye disease can involve levator/Müller fibrosis and other mechanical or neural factors; it is not explained by those muscles alone. Apparent opposite-lid retraction may be compensation for ptosis and can fall when the ptotic lid is raised, but this observation alone does not diagnose thyroid disease or establish the surgical plan. 1

What are the main learning points?

Match correction to cause and protect the ocular surface.

When is assessment urgent?

New ptosis with headache, pupil change, diplopia or weakness, or painful corneal exposure needs urgent assessment.

References and access status

  1. 1
    Immutable original export; original teaching attribution unchecked

    Complete export read; original attribution and any recording/transcript or appointment not independently verified.

  2. 2
    AAO: Acquired ptosis evaluation and management

    Selected indexed official clinical text read on 2026-11-09; full document and operative protocol not appraised.

  3. 3
    2019 RCT: everting sutures versus lateral tarsal strip

    Selected indexed official clinical text read on 2026-11-09; full document and operative protocol not appraised.

  4. 4
    2019 RCT: LTS with everting sutures versus Quickert procedure

    Selected indexed official clinical text read on 2026-11-09; full document and operative protocol not appraised.

Original lecture link